50 KLD ETP Plant Manufacturer & Supplier in Chennai
RRR ENVIRO SYSTEMS provides industrial Effluent Treatment Plant (ETP) solutions for suitable wastewater applications, including plant supply, installation, commissioning, maintenance, revamping and AMC/O&M services in Chennai and surrounding industrial areas.
50 KLD Industrial Effluent Treatment Plant
Looking for a 50 KLD ETP plant in Chennai for your industrial wastewater treatment requirement? RRR ENVIRO SYSTEMS supports industrial clients with ETP plant design coordination, equipment supply, installation, commissioning, existing plant troubleshooting and performance improvement based on the wastewater characteristics and project requirements.
A 50 KLD ETP has a nominal treatment capacity of 50 kilolitres per day. The actual hydraulic and treatment design must be selected according to wastewater flow, operating hours, pH, COD, BOD, TSS, oil and grease, dissolved solids and applicable discharge or reuse requirements.
50 KLD ETP Plant Supply & Services
ETP Plant Supply
Supply of an ETP package and associated equipment based on the approved project design and scope.
Erection & Commissioning
Equipment installation, interconnecting piping, electrical coordination, testing and commissioning support.
ETP Plant Maintenance
Inspection and troubleshooting of pumps, mixers, aeration equipment, dosing systems, valves and filters.
ETP Plant Revamping
Assessment and improvement of existing ETP systems experiencing treatment, hydraulic or equipment issues.
Filter Media Replacement
Replacement of suitable pressure sand filter and activated carbon filter media, where applicable.
AMC & O&M Services
Planned maintenance, operational support and service visits according to the agreed maintenance scope.
ETP Treatment Process – Based on Wastewater Analysis
The process flow for a 50 KLD ETP is selected after evaluating the wastewater source, laboratory analysis, required treated-water quality and site conditions. Depending on the application, the treatment scheme may include the following stages:
1. Collection & Equalisation
Collection and flow equalisation to manage wastewater variations before subsequent treatment.
2. pH Correction & Dosing
pH adjustment and suitable chemical dosing, selected according to wastewater test results.
3. Mixing & Flocculation
Flash mixing and flocculation where required for chemical treatment and suspended-solids removal.
4. Settling & Clarification
Settling or clarification equipment selected to suit the expected solids load and treatment process.
5. Biological Treatment
Biological treatment may be considered for biodegradable wastewater when supported by the design basis.
6. Filtration & Sludge Handling
Suitable polishing filters and sludge-handling arrangements, if required by the approved scheme.
Not every ETP requires all the stages listed above. The final process flow and equipment selection are confirmed after technical evaluation.
Equipment That May Be Included
Depending on the selected process and quotation scope, a 50 KLD ETP package may include:
- Collection and equalisation tank arrangements
- Effluent transfer pumps and process pumps
- pH correction and chemical dosing systems
- Flash mixer and flocculator, where required
- Settling tank or clarifier arrangements
- Biological treatment equipment, where applicable
- Pressure sand filter and activated carbon filter, where required
- Sludge transfer and sludge dewatering arrangements, if specified
- Pipelines, valves, instruments and electrical control panel
Industries We Serve
ETP solutions and maintenance support for suitable wastewater applications across industrial and commercial facilities, including:
Manufacturing Units
Industrial process wastewater and equipment maintenance requirements.
Food & Beverage
Wastewater treatment systems for suitable food-processing applications.
Engineering Industries
ETP maintenance and treatment upgrades according to wastewater composition.
Automotive & Ancillary
Industrial effluent treatment and existing plant service support.
Textile & Process Units
Process-specific treatment assessment and equipment service.
Industrial Facilities
ETP operation support, consumables, spares and preventive maintenance.
50 KLD ETP Plant Services in Chennai Industrial Areas
RRR ENVIRO SYSTEMS supports ETP plant enquiries, maintenance and project requirements in Chennai and selected surrounding industrial locations.
Why Contact RRR ENVIRO SYSTEMS?
- ETP plant supply and service support from one company.
- Existing ETP maintenance, troubleshooting and revamping assistance.
- Support for pumps, dosing systems, filtration equipment and plant spares.
- Technical-commercial proposals based on the available project information.
- Service and AMC/O&M scope can be discussed according to site requirements.
Frequently Asked Questions
What does 50 KLD mean in an ETP plant?
50 KLD means a nominal treatment capacity of 50 kilolitres per day. The actual equipment design depends on the operating schedule and wastewater characteristics.
Can RRR ENVIRO SYSTEMS service an existing 50 KLD ETP?
Yes. Existing ETP inspection, troubleshooting, equipment maintenance and revamping requirements can be discussed after reviewing the plant and its operating issues.
What information is needed for a 50 KLD ETP quotation?
Share the wastewater source, flow rate, operating hours, available wastewater analysis, required treated-water quality, site details and the intended discharge or reuse application.
Can the treated water be reused?
Reuse suitability depends on the wastewater characteristics, treatment design, required reuse quality and applicable regulations. Additional treatment may be necessary.
Does RRR ENVIRO SYSTEMS provide AMC and O&M?
AMC and operation and maintenance support can be discussed according to the plant configuration, site location and agreed scope of work.
Enquire About a 50 KLD ETP Plant
Contact RRR ENVIRO SYSTEMS for industrial ETP plant supply, installation, commissioning, maintenance, revamping and AMC/O&M enquiries in Chennai.
RRR ENVIRO SYSTEMS
No. 7, 11th Cross Street, Dhandeeshwaram, Velachery, Chennai – 600042, Tamil Nadu, India.
Phone: 9962395875
WhatsApp: 9710035249
Email: rrrenviro@gmail.com
